Capabilities · ETAP-powered
Electrical Studies.
Design validation, load flow and short-circuit studies, protection coordination, and arc-flash safety — modeled in ETAP to ANSI/IEC standards.
5,000+
device library
6
study families
Six study families, one validated model of your plant.
Our electrical system modeling in ETAP validates designs before they're built — load flow, short circuit, protection coordination, arc flash, grounding, transients, and power management. Expand each family below for the full study list.
Platform
- ·Core module (64-bit)
- ·Integrated 1D, 2D, 3D & 4D systems
- ·Online Graphical User Interface (GUI)
- ·Intelligent electrical diagram
- ·Auto-busbar layout & design
Workflow
- ·Templates & one-click modeling
- ·Data tables & study results
- ·Voltage propagation & error checking
- ·Unlimited networks & device analysis
Structure
- ·Protective device & panel systems
- ·3D & orthogonal database
- ·Switching configurations & graphical views
- ·Access control & security
Ampacity & Sizing
- ·IEEE 399, NEMA, ICEA P-54-440
- ·IEC 60544, IEC 60287, IEC 60502
- ·BS 7671, NFC 15-100
Underground Thermal Analysis
- ·Neher-McGrath & IEC 60287 methods
- ·Transient temperature calculation
Cable Pulling
- ·Sidewall pressure & tension evaluation
- ·3D conduit layout & views
Network Analysis
- ·Load power & voltage drop
- ·Unbalanced load flow
- ·Single load flow (AC, DC, unbalanced)
- ·Short circuit
- ·Harmonics & filtering
- ·Voltage stability
- ·Contingency & reliability assessment
- ·Load allocation
- ·Transformer sizing
Network Optimization
- ·Optimal power flow
- ·Optimal capacitor placement
- ·Unit transformer tap optimization
- ·Switching optimization
DC Modeling & Analysis
- ·Battery sizing
- ·Battery discharge
- ·DC load flow
- ·DC short circuit
- ·Access control & security
Protective Device Analysis
- ·Start-up protection & selectivity
- ·Protection zone calculation
- ·Zone selectivity model
- ·Voltage drop study & relay characteristics
- ·Device sequence of operation
- ·Device library (5,000+ devices)
Arc Flash Analysis
- ·Arc flash (IEEE 1584-2018, NFPA 70E, BGIA/GUV I-SIBE B&D)
- ·High voltage arc flash (OSHA)
- ·DC arc flash (NFPA 70E 205.D 5.1–5.3)
- ·Arc flash calculators & graphical analysis
- ·PPE requirements & work-permit customization
System Grounding & Earthing
- ·IEEE 80 grounding systems
- ·Finite element method
- ·Protective earthing conductor sizing
- ·Electric shock protection
Dynamic Modeling
- ·User-defined dynamic model (UDM)
- ·Frequency-dependent regulation
- ·Generator, motor, wind turbine, battery, HVDC, SVC, FACTS modeling
- ·Converters & energy storage
- ·Automatic relay & switching actions
- ·Microgrid modeling
Transient Simulation
- ·System stability
- ·Transformer start-up
- ·Dynamic load modeling
- ·Fault interruption & trip sequences
Model-Driven PMS
- ·Intelligent monitoring
- ·Predictive simulation
- ·Situational awareness
- ·Event playback
- ·Load forecasting
- ·Energy accounting
- ·State estimation
- ·Alarm management
Microgrid Management System
- ·Generation optimization
- ·Energy storage management
- ·Generation & load forecasting
- ·Demand side management
- ·Economic dispatch
- ·Supervisory control
- ·Unit commitment
- ·Volt/VAR optimization — VVO
Model-Driven EMS
- ·Network security analysis
- ·Equipment maintenance scheduling
- ·Automatic generation control
- ·Economic dispatch
- ·Unit commitment
- ·Interchange scheduling
- ·Reserve management
Studies performed to
Trademarked product lines
From studies to running systems.
iSub™
Intelligent Substation
- ·Substation automation
- ·Switching order management — SOM
- ·Switching sequence validation
- ·Load & demand-side management
ILS™
Intelligent Load Shedding
- ·Instantaneous load shedding
- ·Optimal load preservation
- ·Automated system restoration
- ·Intelligent subsystem islanding
iCE™
Intelligent Control Enterprise
- ·Programmable controller + RTU
- ·Secure, fault-tolerant hardware
- ·Built-in redundancy
- ·Wireless communications
eSCADA™
Model-Driven Electrical SCADA
- ·Web-based dashboards & HMI
- ·Historian & sequence-of-event management
- ·Geographical monitoring
- ·Redundant architecture
Start the conversation


